Every figure is your meter reading. Idle draw and changeover energy are never estimated — leave them blank and the split is not stated. Runs in your browser; nothing is stored.
A site meter divided by output cannot say which press is the inefficient one, or how much of the energy made no product at all — the hours a heated barrel sat at temperature between jobs, the purge and warm-up at every changeover. On batch work those scale with the number of runs, not the kilograms, which is exactly what a per-kilogram figure hides.
So each machine is compared with the best in its own group — same process, same building, same product mix — on the energy that actually made product. A machine that only idled more is not called inefficient; it is called badly scheduled, which has a different fix.
Your machines, over one period
The same period for every machine — a month is typical. Idle draw and changeover energy are optional and must be measured, not estimated: leave them blank and the split is simply not stated. The starter figures are an example to overwrite.
Machine
Process
Energy
Metered kWh
Output, kg
Idle hours
Idle draw, kW
Changeovers
kWh per changeover
What the meters say
Matching each machine to the best in its group would save about 8,723 kWh over the period entered — measured against your own machines, not a benchmark. Where idle and changeover energy were measured, 15% of the meter made no product.
Press 1
1.079 kWh/kg metered · 0.937 productive
13% of this machine's energy made no product. Changeovers add 0.042 kWh to every kilogram — a figure set by the number of runs, not the kilograms, so longer runs cut it directly. Running at Press 3's intensity would have used about 584 kWh less over the period.
Press 2
1.444 kWh/kg metered · 1.148 productive
21% of this machine's energy made no product. Changeovers add 0.064 kWh to every kilogram — a figure set by the number of runs, not the kilograms, so longer runs cut it directly. Running at Press 3's intensity would have used about 8,139 kWh less over the period.
Press 3
0.984 kWh/kg metered · 0.922 productive
6% of this machine's energy made no product. Changeovers add 0.013 kWh to every kilogram — a figure set by the number of runs, not the kilograms, so longer runs cut it directly.
A retrofit case for one machine
Enter the energy per kilogram the supplier quotes for the new machine or retrofit, and its cost. It is judged against this machine's own readings, not the maker's idea of it.
Energy per customer order
For a customer who asks about their parts rather than your plant average. Each order carries its kilograms at the machine's productive intensity plus its own changeovers; idle time between orders belongs to no order and is shown separately. The two orders are an example to overwrite.
Order
Machine
Kilograms
Changeovers
Order 4471 — 2,000 lids: 204 kWh on Press 1, 1.132 kWh per kg, 0.04 t CO₂e of machine energy. 17% of it is changeover — a short run, costing more per kilogram than the 0.979 its orders carry on average.
Order 4480 — 60,000 lids: 5,095 kWh on Press 1, 0.944 kWh per kg, 0.94 t CO₂e of machine energy. 1% of it is changeover — a long enough run to sit at or below the 0.979 its orders carry on average.
Not allocated to any order: 13,670 kWh of measured idle running over the period. It is a plant cost, and spreading it by kilograms would be a choice presented as a measurement.
Machine energy only, at the UK Government factor for the energy selected, including its supply chain. The materials in an order come from the product's own assessment.